<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>altim</ParameterFamily>
<LongName>
plate_drop_delay
</LongName>
<Name>
pdd
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_VLF_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
The time in seconds the firmware will waits after the load table is locked in
the 'up' position until the table vacuum is released allowing the plate to
drop into the leading edge clamp.
</text></DescriptionText>
</Description>
<Type>
uint32
</Type>
<Default>
<UnnumberedList>
<li>1.500 seconds</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 10.000 seconds</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
This parameter is stored as an integer value of milliseconds.  It is entered
by the user in seconds and displayed to the user in seconds. The user may enter
up to three digits after the (optional) decimal point.
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:34 2008 PST
</Updated>
<Links>
</Links>
</Parameter>